Commercial restrooms—airports, shopping malls, office towers—demand sensor products that perform flawlessly for years, not months. A sensor faucet or flusher that fails after a low cycle count means costly repairs, unhappy facility managers, and a damaged brand reputation.
So how do we ensure our sensor components and finished products (faucets, urinal & squatting pan flushers, soap dispensers) survive real-world commercial abuse? Through a rigorous, multi-stage testing protocol.
1. Cycle endurance testing
We run our solenoid valves and sensors continuously for over 500,000 cycles. This simulates 5–8 years of heavy public restroom use. Any mechanical or electronic weakness is exposed before shipment.
2. Environmental stress tests
Commercial restrooms are wet, steamy, and chemically harsh. We test with:
IP65+ water ingress protection
Salt spray corrosion (for exposed metal parts)
Temperature cycling from 0°C to 60°C
High humidity (95% RH) for 48+ hours
3. False-trigger immunity
We expose sensors to varying light conditions, electromagnetic wave interference, and nearby movements. Our adaptive algorithms filter out noise while keeping true detection fast and reliable.
4. Power fluctuation & surge testing
Battery-powered or DC sensors must handle voltage drops. We test down to the cutoff threshold and verify consistent performance without resetting or mis-triggering.
5. 100% factory burn-in
Every single unit—whether a control module or a complete sensor faucet—runs through a full functional test under simulated commercial conditions. No random sampling. No shortcuts.
The result
You get proven, long-life sensor solutions that reduce callbacks and warranty claims. Whether you need OEM components or private-label finished goods, we deliver commercial-grade reliability.
Put our tests to work for you. Contact us today for test reports and a custom quote.